Bidirectional piezoelectric (tension compression) dynamic force sensor

No.3001A、3010A 、3001LA、3010LA

Dynamic measurement has fast response, wide frequency range, long static calibration duration, small sensitivity error in tension and compression, and high re-usability.

  • Bidirectional piezoelectric (tension compression) dynamic force sensor
  • Bidirectional piezoelectric (tension compression) dynamic force sensor
  • Bidirectional piezoelectric (tension compression) dynamic force sensor
  • Bidirectional piezoelectric (tension compression) dynamic force sensor
Desciption

Product

Bidirectional piezoelectric (tension compression) dynamic force sensor

MODE

KD

3001A

3010A

IEPE Type  MODE

3001LA

3010LA

Measuring Range

KN

1-2

5-10

PE Type Sensitivity

pC/N

3.5

3.5

IEPE Type Sensitivity

mV/N

5000-1000

1000-500

Resonant Frequency

Hz

>70kHz

>40kHz

Nonlinear

%FSO

≤1

≤1

Sensitivity error of tension and compression

%

≤2

≤2

repeatability

%FSO

≤1

≤1

 Insulation Resistance

Ω

>1013

>1013

 Operating Temperature

-40~120

-40~120

 Permitted Overload

%

120

120

PE Type Matching instruments

/

Charge Amplifier

Charge Amplifier

IEPE Type Matching instruments

/

Constant current adapter

Constant current adapter

Shell Material

/

High-strength Stainless steel

High-strength Stainless steel

Sealing Form

/

Laser Welding

Laser Welding

Sensing Element

/

quartz

quartz

Installation Method

/

2-M5

2-M12

Output Method

/

Side end L5

Side end

L5

 External Dimensions

mm

Φ16*17.5

Φ26*48

Weight

gram

~15g

~146g

Specifics

Dynamic measurement has fast response, wide frequency range, long static calibration duration, small sensitivity error in tension and compression, and high re-usability.

Application

Dynamic stretching and compression, measurement of impact, vibration force, reverse thrust, dynamic force of vibration table, collision force, support force, and impact force.

Connecting cables

2-meter dual ended L5 low noise cable.

Options

Installation fixture (customized); Engineering box (optional).